Optical thermal detector ACOT
Conventional optical-thermal smoke and temperature detector
Conventional white optical-thermal smoke and heat detector. Requires a standard base (Ref. BS) or a tall base for exposed piping (Ref. BSA). Dimensions: 100 mm Ø x 30 mm. CPR-certified to EN 54-7
Productos relacionados
Resettable analogue alarm push button WXCPIP
Red resettable analogue alarm push button with LED and cover for outdoor use, IP65
Resettable analogue red alarm call point with LED and cover, surface-mounted, CPR EN54-1 certified. IP65. Addressing via QR code reading and features a built-in short-circuit isolator.
12-zone/6-loop hybrid panel ZX12-16PRO
12-zone/6-loop hybrid panel expandable to 16 zones/8 loops for conventional/analog detection and EH-SYNC® network connection. Touch display, USB/Bluetooth/Ethernet/WiFi/4G.
Hybrid panel with 12 zones or 4 loops, expandable to 16 zones or 8 loops via a 4-zone detection card (Ref. TLZX). Capable of combining up to 32 analog and conventional elements per zone and up to 64 per loop. Features direct connection to the EH-SYNC® panel network and a 2.7″ multi-language TFT touchscreen with a log of up to 10,000 events. 2 supervised programmable 24V I/O. 300mA. 2 independent relay outputs for alarm/fault.
Configuration and commissioning from the panel itself or via on-board USB and/or Bluetooth ports using the Tools® app, without the need for additional cards. MODBUS protocol available via Ethernet port. Ethernet and Wi-Fi ports included, with optional 4G module (ref. W4G) for remote management and access to the Nusku® platform. Includes a license for CMS connection services, remote maintenance, remote system programming, and video verification via camera (Ref. WCON) with direct connection to zone or loop.
White RAL 9010 ABS plastic housing for surface or flush mounting. Dimensions 360mm. x 400mm. x 100mm. CPR EN54-2, EN54-4, EN54-13, and EN54-21 certified. Requires two 12V/7Ah batteries, not included.
“
Velocimetric thermal detector ACT
Conventional thermal-thermovelocimetric temperature detector
Conventional programmable thermal-thermovelocimetric temperature detector, white. Requires a standard base (Ref. BS) or a tall base for exposed piping (Ref. BSA). Dimensions: 100 mm Ø x 30 mm. CPR-certified to EN 54-5, Grade 2.
Algorithmic optical smoke detector AXO-I
Algorithmic optical smoke detector
Optical algorithmic smoke detector featuring DM SENSOR technology, which enables the storage of data from the 5 minutes prior to a fire alarm. When the system is connected to the NUSKU® platform with AI technology, it compares the received algorithms and logic curves, providing the detector with new algorithms and continuously optimising the detection of false alarms.
Colour: white. Requires a standard base (Ref. BS) or a high base for exposed piping (Ref. BSA). Dimensions: 100 mm Ø x 30 mm. CPR EN54-7 certified. Addressing via QR code reading and features a built-in short-circuit isolator.