Algorithmic Detection Systems
Showing 1–20 of 34 resultsSorted by latest
LX1C 1-Loop Algorithmic Detection Panel
1-loop algorithmic detection panel with capacity for up to 120 devices. USB/Bluetooth/Ethernet/WiFi/4G touchscreen display.
1-loop algorithmic detection panel with capacity for up to 120 devices, 2.7″ multi-language TFT touchscreen display with logging for up to 10,000 events, 2 programmable supervised 24V I/O. 300mA. 2 independent relay outputs for alarm/fault.
Configuration and commissioning via on-board USB and/or Bluetooth port, no additional card required. Communications for remote management and access to the Nusku® platform via included Ethernet and Wi-Fi ports, and optionally with a 4G module (ref. W4G). MODBUS protocol available via Ethernet port.
White RAL 9010 ABS plastic housing for surface or flush mounting. Dimensions: 200mm x 290mm x 80mm. CPR EN54-2, EN54-4, EN54-13, and EN54-21 certified. Two 12V/2Ah batteries required, not included.
LX1 1-Loop Algorithmic Detection Panel
1-loop algorithmic detection panel with capacity for up to 250 devices. USB/Bluetooth/Ethernet/WiFi/4G touchscreen display.
1-loop algorithmic detection panel with capacity for up to 250 devices, a 2.7″ multi-language TFT touchscreen display with up to 10,000 event logs, and 2 supervised 24V programmable I/O. 300mA. 2 independent relay outputs for alarm/fault. Configuration and commissioning via onboard USB and/or Bluetooth port, no additional card required.
Communications for remote management and access to the Nusku® platform via included Ethernet and Wi-Fi ports, with optional 4G module (ref. W4G). MODBUS protocol available via Ethernet port.
White RAL 9010 ABS plastic enclosure for surface or flush mounting. Dimensions: 360 mm x 400 mm x 100 mm. CPR certified EN54-2, EN54-4, EN54-13 and EN54-21. Requires two 12 V/7 Ah batteries (not included).
1-Loop Algorithmic Detection Panel BX1-2PRO
1-Loop algorithmic detection panel, expandable to 2, with capacity for up to 350 devices per loop. USB/Bluetooth/Ethernet/WiFi/4G touchscreen display.
1-Loop algorithmic detection panel, expandable to 2 loops via loop card (ref. TLBX), with capacity for up to 350 devices per loop, with connection to NETCOM® panel network via network card (Ref. T-NETCOM), 2.7″ multi-language TFT touchscreen display with logging of up to 10,000 events, 2 supervised 24V programmable I/O. 300mA. 2 independent relay outputs for alarm/fault.
Configuration and commissioning via USB port and/or onboard Bluetooth without the need for an additional card. Communications for remote management and access to the Nusku® platform via included Ethernet and Wifi ports, and optionally with a 4G module (ref. W4G). MODBUS protocol available via Ethernet port.
White RAL 9010 ABS plastic enclosure for surface or flush mounting. Dimensions: 360 mm x 400 mm x 100 mm. CPR certified EN54-2, EN54-4, EN54-13 and EN54-21. Requires two 12 V/7 Ah batteries (not included).
BX1-4MAX 1-loop algorithmic detection panel
1-loop algorithmic detection panel, expandable to 4 loops, with capacity for up to 350 devices per loop. Touchscreen display and removable graphic tablet. USB/Bluetooth/Ethernet/Wi-Fi/4G.
1-loop algorithmic detection panel, expandable to 4 loops via loop card (ref. TLBX), with capacity for up to 350 devices per loop, featuring NETCOM® panel network connection via network card (Ref. T-NETCOM), a 2.7″ multi-language TFT touchscreen display with logging for up to 10,000 events, and a removable 10″ graphic tablet for system configuration, graphic management, and interface with the Nusku® platform.
Configuration and commissioning via on-board USB and/or Bluetooth, no additional card required. 2 supervised programmable 24V I/O. 300mA. 2 independent relay outputs for alarm/fault. Communications for remote management and access to the Nusku® platform via included Ethernet and Wi-Fi ports, and optionally with a 4G module (ref. W4G). MODBUS protocol available via Ethernet port.
RAL 7035 gray metallic casing for surface or flush mounting. Dimensions: 490 mm x 420 mm. x 100mm. CPR EN54-2, EN54-4, EN54-13, and EN54-21 certified. Four 12V/7Ah batteries required, not included.
“
LX2 2-loop algorithmic detection panel
2-loop algorithmic detection panel with capacity for up to 250 devices per loop. USB/Bluetooth/Ethernet/Wi-Fi/4G touch display.
2-loop algorithmic detection panel with capacity for up to 250 devices per loop, 2.7″ multi-language TFT touch screen with a log of up to 10,000 events, and 2 supervised 24V programmable I/Os. 300mA. 2 independent relay outputs for alarm/fault.
Configuration and commissioning via on-board USB and/or Bluetooth without the need for an additional card. Communications for remote management and access to the Nusku® platform via included Ethernet and Wi-Fi ports, and optionally with a 4G module (ref. W4G). MODBUS protocol available via Ethernet port.
White RAL 9010 ABS plastic housing for surface or flush mounting. Dimensions 360mm. x 400mm. x 100mm. CPR EN54-2, EN54-4, EN54-13, and EN54-21 certified. Two 12V/2Ah batteries required, not included.
Algorithmic detection panel for NETCOM® 1-loop network RAX LX1
Algorithmic detection panel for NETCOM® single-loop network. USB/Bluetooth/WiFi/4G.
Algorithmic detection panel for NETCOM® single-loop network with capacity for up to 120 devices, 2.7″ multi-language TFT touchscreen with log capacity for up to 10,000 events, 2 programmable 24V monitored I/O. 300mA. 2 independent relay outputs for alarm/fault.
Configuration and commissioning via onboard USB and/or Bluetooth port, no additional card required. Communications for remote management and access to the Nusku® platform via the included Wi-Fi port and optionally with a 4G module (ref. W4G). MODBUS protocol available via Ethernet port.
White RAL 9010 ABS plastic enclosure for surface or flush mounting. Dimensions: 200 mm x 290 mm x 80 mm. CPR EN54-2, EN54-4, EN54-13 and EN54-21 certified. Requires two 12 V/2 Ah batteries (not included).
Base with siren and analogue flash WXBSF
Base with siren and analogue optical acoustic flash
Base with siren and analogue optical acoustic flash. 32 main tones and 32 alternative tones, acoustic level up to 92db. 130mm Ø x 28mm. CPR EN 54-23 certified. Addressing via QR code reading and built-in short-circuit isolator.
Standard connection base BS
Standard connection base for detectors and cameras
Standard connection base for detectors in the AC, AX and JN ranges. Colour: white. Dimensions: 100 mm Ø x 9 mm.
Standard connection base BSN
Standard connection base for detectors and camera, black colour
Standard connection base for detectors in the AC, AX and JN ranges. Colour: black. Dimensions: 100 mm Ø x 9 mm.
Connection base for exposed pipe BSA
Connection base for exposed pipe for detectors and camera
Connection base for 20 mm exposed pipe for detectors in the AC, AX and JN ranges. Colour: white. Dimensions: 100 mm Ø x 28 mm.
Connection base for exposed pipe BSAN
Base de connexion pour tube apparent pour détecteurs et caméra, couleur noire
Connection base for 20 mm exposed pipe for detectors in the AC, AX and JN ranges. Colour: black. Dimensions: 100 mm Ø x 28 mm.
Camera for connection to zone or loop WCON
Camera for direct connection to zone or loop
Camera for direct connection to zone or loop that provides incident or alarm image for video verification. Addressing via QR code reading.
Algorithmic optical smoke detector AXO-I
Algorithmic optical smoke detector
Optical algorithmic smoke detector featuring DM SENSOR technology, which enables the storage of data from the 5 minutes prior to a fire alarm. When the system is connected to the NUSKU® platform with AI technology, it compares the received algorithms and logic curves, providing the detector with new algorithms and continuously optimising the detection of false alarms.
Colour: white. Requires a standard base (Ref. BS) or a high base for exposed piping (Ref. BSA). Dimensions: 100 mm Ø x 30 mm. CPR EN54-7 certified. Addressing via QR code reading and features a built-in short-circuit isolator.
Algorithmic Optical Smoke Detector AXON-I
Black algorithmic optical smoke detector
Optical algorithmic smoke detector featuring DM SENSOR technology, which enables the storage of data from the 5 minutes prior to a fire alarm. When the system is connected to the NUSKU® platform with AI technology, it compares the received algorithms and logic curves, providing the detector with new algorithms and continuously optimising the detection of false alarms.
Colour: black. Requires a standard base (Ref. BS) or a high base for exposed piping (Ref. BSA). Dimensions: 100 mm Ø x 30 mm. CPR EN54-7 certified. Addressing via QR code reading and features a built-in short-circuit isolator.
Thermal-thermovelocimetric detectorAXTN-I
Black algorithmic thermal-thermovelocimetric temperature detector
Algorithmic thermal-thermovelocimetric temperature detector featuring DM SENSOR technology, which enables the storage of data from the 5 minutes prior to a fire alarm. When the system is connected to the NUSKU® platform with AI technology, it compares the received algorithms and logic curves, providing the detector with new algorithms and continuously optimising the detection of false alarms.
Colour: black. Requires a standard base (Ref. BS) or a high base for exposed piping (Ref. BSA). Dimensions: 100 mm Ø x 38 mm. CPR EN54-5 certified. Addressing via QR code reading and features a built-in short-circuit isolator.
Mini isolator module MOXA
Mini short-circuit isolator module
Mini short-circuit isolator module for installation in ZX, LX and BX panel loops. No external power supply required. Supplied with white box. Dimensions: 40 mm x 40 mm x 20 mm.
Mini Analog Module 1I MOXI
Mini analogue module with 1 technical input
Mini analogue module with 1 programmable input for receiving technical signals from NO or NC contacts. For installation in LX and BX panel loops. No external power supply required. Supplied with white box. Dimensions 40 mm x 40 mm x 20 mm. Addressing via QR code reading and built-in short-circuit isolator.
Mini analogue module with 1 relay output MOXO
Mini analogue module with 1 relay output
Mini analogue module with 1 relay output programmable as NO or NC contact. Max. current 1A. For installation in LX and BX panel loops. No external power supply required. Supplied with white box. Dimensions 40mm x 40mm x 20mm. Addressing via QR code reading and built-in short-circuit isolator.
2-zone analogue module MDX2Z
Analogue module with 2 conventional detection zones
Analogue module with 2 conventional detection zones. For installation in LX and BX panel loops. No external power supply required. Supplied with white box. Dimensions: 150 mm x 110 mm x 46 mm. Addressing via QR code reading, occupies 2 addresses in the loop and has a built-in short-circuit isolator.
Analog module with 3 inputs MDX3I
Technical 3-input analogue module
Analogue module with 3 programmable inputs for receiving technical signals from NO or NC contacts. For installation in LX and BX panel loops. Occupies 3 addresses in the loop. No external power supply required.
Supplied with white box. Dimensions: 150 mm x 110 mm x 46 mm. Addressing via QR code reading, occupies 3 addresses in the loop and has a built-in short-circuit isolator.